gas fireplace troubleshooting flame goes out
Like any appliance that uses a pilot light, gas fireplaces can have theirs go out as well. Troubleshooting then becomes easy. So it's best to do some research on your particular make and model before attempting any repairs. Sprayed everything mentioned above. You're more likely going to cause a house fire if you don't clean the dust out. An oxypilot is an atmospheric sensing device in place to put out the gas fire if there is insufficient oxygen in the room. The fire keeps on going out about 30mins to an hour. Temp/Timer Mode= If the ambient room temp changes, the flame height will adjust automatically to maintain set temp and the fire will continue to function normally. If your fireplace is new, there may be what is known as “off-gassing,” caused by residual factory paints burning off. As its December I decided to try your trick with a straw. Unfortunately, all three parts were obsolete. I finally replaced the light switch that controls the fireplace and that solved the problem. 2. Between the pilot supply pipe and the pilot burner, there's a brass tail or connector. It's a saftey mechanism in case the flame doesn't light so gas doesn't fill the chamber. This removes FUD (Fear, Uncertainty and Doubt). They will test to ensure your thermocouple or thermopile are working, and fix any loose or inadequate wiring. The tank may be exhausted. IDIOT. Fantastic! Amazing. Thank you for the advice. Blow down through the straw to clean it out. When pilot light goes out, usually the cause is something you can solve easily. If you’re in the DC, Maryland, or Virginia give us a call! Your pilot light should be sky blue in the middle and dark blue in the outer flame. Get Your Gas Appliances Serviced Every Year. Thanks for sharing the information. Pilot lights can be blown out by an interrupted flow of gas or from a strong draft. It has been working normally for a couple of weeks now. Sometimes it will light, others it won't. It is designed as a safety device to protect you from carbon monoxide poisoning if the air in a room becomes vitiated. The current generated in the circuit is proportional to the temperature difference. If you continue to have lighting issues past this you may need to take a closer look at the thermocouple or thermopile. I also know where i would draw the line and call in a pro. Any advice? Knowledge is money, I am sorry if my post have affected your income. try to turn back knob but it locks have to turn back and forth to unlock knob by a click then start all over. These are possible causes and troubleshooting for flame cutting out on that unit according to Heat n Glow's own manual for that product. Do you know how to test safety devices? Mark is 100% bang on with what he is saying. View this video for steps you can take to troubleshoot. But unfortunately, the parts are no longer available. Sone how it worked. I hired 4 different Companies to fix them. Some have only a thermocouple, and some have an oxypilot (an atmospheric vitiation sensing device). It’s worth testing your batteries to make sure you don’t just need a fresh set. Among the causes of problems with gas fireplace burners are: Wiring that is faulty, damaged, or unattached could be the cause of a burner that won’t light. This could be a problem with the thermopile, which needs replacing at some point in the product life of your gas fireplace. The pilot was quite reaching the thermo couple thermo pile. Can you check that a flue is pulling correctly? Thanks again! If you experience a problem while using the Casting Radiance model, it may be easily fixed be performing a simple troubleshooting routine. I followed your directions & the diagram along with the straws. I told him about your straw trick and what do you know... my fireplace is now working!! If the batteries in either of these are dead, it could prevent your fireplace from igniting. Phone: (202) 289-2750 • dchighschimney@gmail.com, Copyright 2020 © Highs Chimney | Service Areas | All Rights Reserved | Web Marketing by Brandtastic, Office hours: Mon – Fri, 8am – 4PM & Sat, 8am – 2pm, 8045 Snouffer School Road Gaithersburg MD 20879, Admin & Marketing Office – No Public Access, High’s Chimney Service of DC • 1200 18th Street NW, Suite 700 Washington D.C. 20036, Phone: (202) 289-2750 • dchighschimney@gmail.com. Improperly Arranged Firebox: Make sure that the embers and logs in your firebox are arranged correctly and according to manufacturer specifications. Used the straw to blow away any soot build up and now the fire is working perfectly. Gas fireplaces will make some noise as part of their normal operation. A quick clean of both pilot outlets & WACKO - IT WORKS!!! I decided to get the certified technician in to do a full service on my gas fire. Chimney: Make sure your chimney is clean and clear of obstructions. If the pilot goes out, relight it and check the flame. Adjusting this to the correct temperature can sometimes solve the ignition problem. This may cost you around £30–£50 or more. Every gas fireplace will have a set of instructions, supplied by the manufacturer, to show you how to reignite the pilot light in the case of failure. If it still doesn’t light after trying these simple gas fireplace troubleshooting tips, or if you are unable to do (or uninterested in doing!) "it is designed as a safety device to protect you from carbon monoxide poisoning if the air in a room becomes vitiated". This is the most dangerous advice I have heard in a long time. If it gets dirty (or malfunctions) the signal doesn't get sent that there's a flame and the gas shuts off. Hold the knob in for 60 seconds, then release it. Pilot light stayed on the whole time though. My empire dvc-35-sp pilot lights and flame goes on, heat blows. Below are some common problems with gas fireplaces and how to fix them: There are several issues that might prevent a gas fireplace from igniting. When you start your fireplace, you may notice condensation on your glass door as water vapor in the air inside the firebox evaporates. There'll be a small hole on one... Then, place a bit of tubing or a drinking straw over each pilot hole. Admin & Marketing Office – No Public Access Great tip. It's your life on the line for the sake of a few quid! All you have to do is go to the gas meter and find the tee – drain the capped pipe that holds the moisture. If you suspect that there is an issue with them delivering gas to your home, or you suspect that your gas was shut off, call your utilities company. Fire would start then suddenly stop the pilot light also went out. Readers want to know how to troubleshoot gas fireplace problems. Improper Airflow: Ensure that there is a proper ratio between the flame’s gas and oxygen; a flame that has too much gas will produce more soot. A strong draft can blow … thank you for helpful advice,never mind nasty comments from some quarters,I have a carbon monoxide detector in the room anyway,so am doubly protected. My elderly parents gas fire kept cutting out. The corgi technician recommended replacing the pilot burner, ignition unit and thermocouple. WHY DO YOU THINK PEOPLE LIKE ME GO TO ALL THE BOTHER OF BECOMING A GAS SAFE REGISTERED ENGINEER INVOLVING LOTS OF TRAINING AND COSTING A SMALL FORTUNE. This repair requires professional expertise. That is a safety switch that will kill the main flame if for some reason the combustion chamber temperature gets above where the fireplace designed to operate at. I used a straw and blew through the 3 gas outlet holes in my Faber gas fireplace. Problem: The flame is on, but no warm air is coming out. burner and the pilot valve from one another. My pilot flame is now blue rather than yellow just as you said. This is harmless and should pass after a few fires. Thanks. Thought not. I am tired of hired people that, fix it long enough to get paid, then they stop working. If the logs are misplaced, they disrupt the flow of the flames, causing soot to be deposited. Tripped Circuit Breakers: When the electrical wiring in your house has too much current running through it, circuit breakers “trip,” or cut off the flow of power to prevent the circuit from overheating. The fireplace pushes fuel through an attached fuel line and with the touch of a button, you light the piece. Though I don't worry too much about carbon monoxide poisoning, I figured there must be some safety device to shut off the gas valve. Many of these tips and diagnoses for these common gas fireplace problems can be done by yourself. Out pilot light would go out after half an hour - some days after 5 minutes. The pilot light for your gas fireplace is an ignition source. Also ensure that your burners are clean; dirty burners can also cause this kind of sound. That be one heck of a service call. Make sure there's no dust blocking this, and clean if needed. The area where the flame comes through isn’t working properly. Phone: 301-519-3500 or 703-550-5115 • mike@highschimney.com One junction is at the temperature to be measured, while the other is held at a fixed lower temperature. You can learn more about these devices below, including how they work and how you might be able to fix yours so that your gas fire won't keep going out. Schedule A Chimney Sweep Before The Fall Rush, Summer Is the Perfect Time for A Fireplace Makeover. The heater is on, but no heat is coming out. Worked perfectly after using the straw. He told me to clean the sensors on the oxypilot with a dollar bill. Do you see any spark? If you have exhausted other solutions and believe you need to test or replace a component like this, make sure the other causes have been ruled out and call a professional to handle it. All it took was for me to blow through a drinking straw over the pilot/thermocouple area to clean them out. Absolutely perfect, it's working like a dream. There'll be a small hole on one side. Thank you !! If turning the knob to the on position doesn’t open the gas flow, contact your propane supplier. Then, place a bit of tubing or a drinking straw over each pilot hole. Highs Chimney • 8045 Snouffer School Road Gaithersburg MD 20879 These units sometimes go bad and need to be replaced. Decided to do the straw trick myself and the fire has been working perfectly ever since! used a straw as above. Also the diagram of how it produces the flame and how it is supposed to work is excellent. It worked!! If the oxypilot becomes blocked with dust or soot, the flame lifts away from the thermocouple or flame sensing electrode. I have a wall mounted insert, there are 2 screws at the top (just above the glass). When you first start the fire, keep it on the pilot light for a couple of seconds, and the fire should "kick on" when you turn the dial from the pilot light to the on position. The ignitor is responsible for turning on your pilot light (the little blue flame) of your fireplace. Many thanks for your advice. This could cause the pilot to go out and subsequently shut down everything. Gas regs there for a reason. Doing the happy dance !!! I told him I was having issues with the fire going out after approx 1 hour. thank you, hope this saves me money I cant afford. Now my fire is working perfectly again. A very useful advice. If it is, simply re-light the pilot with a match or a lighter to see if the fireplace turns back on.Alternatively, if the flame reignites initially but the pilot won't stay on, there are more i… Excellent advice, I was going to replace thermocouple , but thought I'd try cleaning the pilot as you described, worked perfectly. Follow the manufacturer’s instructions to relight the pilot. Thank you! To check the igniter, turn the gas on and press the button. When there is a need to ignite the gas, the thermocouple is the go-to part. There is absolutely no danger in this diy fix. Takes about 6 try's what part do i need? Note that this may cause the flame to appear more blue than orange. Try relighting the pilot and jump out the switch at the gas valve and see what happens. Thanks for the help. There is a reason why the gas industry is so heavily regulated, because fatalities can easily occur when people play with things they don't understand. Valve will turn to pilot flame if the set temp & ambient temp remain the same over a 6 hour period. Oxy Pilots don't detect CO they detect the absence of Oxygen. Hiring a CORGI engineer to service the fire involves removing the gas fire and checking the chimney with a smoke pellet. Fixed! It hasn't let us down ever since. Symptom: The pilot is burning, there is no burner fl ame, the valve knob is in the ON position, and the ON/OFF … If the smell persists, check that your chimney is not obstructed and is cleaned. Call a technician, like High’s Chimney, to determine if it needs a replacement. In many cases, if the thermocouple is the source of a problem, it … Clogged Burners: Clogged or broken burners can also cause excess soot build up. them yourself, then call B&C and have Bob come out to do an inspection. Thank you best wishes. So we chose to leave it. Watch this video and learn how to troubleshoot any problems you may have with your Majestic gas fireplaces. Thermocouple, Thermopile, and Wiring: The thermocouple is a metal probe that controls the gas valve, sensing the temperature and generating electricity to ignite the gas if necessary. Basically, if the oxygen percentage in a room drops, the flame shape is altered by its incomplete combustion. Blow down through the straw to clean it out. This, in turn, makes the gas valve shut off. Tried doing this and will continue to try. i would have never thought of the straw...genius! Took me a little while to find the small hole at the base of the pilot supply pipe but blew that out with the straw and now have a very healthy pilot light reaching both the thermo couple and the thermo pile. If the thermocouple is working, the pilot should remain lit. The thermocouple and thermopile are the two most common reasons why a gas fireplace won’t stay lit. However... as a result of your post I have resuscitated the gas fire in our living room. Call in a gas engineer. There may be some buildup over time of condensation residue, but this is easily wiped away. Debris in or around the gas holes made my pilot flame burn sluggish (and yellow). High’s Chimney Service of DC • 1200 18th Street NW, Suite 700 Washington D.C. 20036 I can light the pilot but when I turn it to the on position to light the burner, it only lights for about 15 seconds, sputters and then goes out. Just what I needed to know .... my fire is doing the same thing. The pilot worked better but no sustaining flame. This would also make the pilot light go out, for the same reason. If the pilot or flame goes out intermittently, check if additional appliances in the house, like the heater, are using the same gas line. Here are some potential causes: Old Batteries: Depending on the type of gas fireplace you own, you may have a remote or receiver that run on batteries. Experts often receive questions about gas fireplaces and related gas fireplace issues. Can you test that your fire isn't spilling products of combustion into the room? When relighting it, make sure that you follow the manufacturer’s instructions carefully. If your fireplace won't turn on, it may be a simple matter of the pilot flame having been blown out. Note that this may cause the flame to appear more blue than orange. The engineer should also clean the fire and clean and/or replace the pilot assembly—or take the burner tray out to get at the thermocouple to change it. Every once in a while, however, there will be issues that need to be addressed. The fire produced by the pilot should be sky blue in the middle and dark blue in the outer flame, rather than a flame tinged with yellow. Well worth the $1.98 investment to give it a try! This article is accurate and true to the best of the author’s knowledge. Many many thanks! I have a Rinnai gas heater its starts but only last for for 3-5 mins then it goes out, Thank you so much for this, quick blow through a straw and my long stored Valor gas heater is now working perfectly again after I couldn't get it lit via the pilot, or to stay alight if I lit it with an external source. The thermopile, like the thermocouple, is a temperature sensor that generates electric voltage. Thermostat: Make sure that the thermostat is set properly; often, the issue is that the thermostat is set lower than the temperature in the room. Worked first time. Through personal research and a DIY ethic, I managed to fix the fault in my gas fire. However, there may be unusual noises caused by external issues. I now want to share my solution with others. Improper Airflow: Ensure that there is a proper ratio between the flame’s gas and oxygen; a flame that has too much gas will produce more soot. Solution: Turn all switches to the “off” position and unplug the unit from the wall for 5 minutes. OMG it worked. No issues...so far. Says it all! The latter kept going out after about half an hour, even when the dial showed it as on. :) thank you!! Technically wrong on so many levels. Used a paper clip and a can of compressed air. It was the part of the pilot flame normally pointing backwards to the thermocouple tip (and normally hitting it directly) that caused the fireplace to automatically "de-couple" since the thermocouple never got hot – a cold thermocouple means that the fireplace thinks the fire is blown out and it stops the gas inlet for for safety reasons. Blew out pilot hole for air made the flame blue like the article says and hey presto big problem fixed......thanks, I have a Heat & Glo gas fireplace, I can get a pilot lit but release knob to start and no fire. The gas technician suggested replacing the pilot burner/igniter/thermocouple. A gas fireplace provides heat for your home but also adds a decorative touch to a living room or common room. Another common culprit is incorrect gas pressure. After doing some research, however, I now have basic knowledge about gas fires and have successfully fixed my gas fire. There are fireplace burner issues that go beyond basic troubleshooting and require professional repair. Fires are the biggest killer of all appliances. This should be located in the firebox. I will try this when I go home as my fire has been playing up for ages which isn't good this weather. Thanks. When they turn on they may be drawing gas away from the fireplace line. This is what a thermocouple looks like (though exact shapes and sizes may vary). If you’re not comfortable doing this, a local chimney sweep will be capable of servicing it for you. I purchased a can of 'compressed Air' on ebay - $13. Here are some typical questions asked by readers and Expert answers. Ensure that they are clean and in working condition. Remove them and then the front face tips out and lifts out of the unit. They are commonly found on newer gas fireplace models in place of a thermocouple. Even if you have solid knowledge of gas fires, you still need a CORGI-registered gas installer to work on gas appliances when you have to break or disconnect any gas supplies or fittings or try to change parts. Saved me a lot of money. When the pilot is lit, there should be two flames: one over the burner and the other (smaller one) touching the thermocouple. This will make the fire cut out, or pilot not light. I am at the end of my rope, I live in a medium side time and have called everyone of them with the Sam results. Total nonsense and dangerous. However, there are other possibilities out there. Soot buildup is normal on vented gas logs, but not on vent-free units. I did what you suggested. Follow the manufacturer’s instructions to increase oxygen and decrease gas flow. Pilot lights can go out for a … To cure the gas fire going out, the corgi technician suggested replacing the pilot burner, ignition unit and thermocouple. Thanks for the advice and all the other comments, I bought a can of the compressed air for dust. Propane Tanks & Natural Gas Lines: If your gas fireplace relies on a propane tank, ensure that it is in the on position and delivering gas; there will be a knob on top of the tank that controls this. (This saved us at least £30.). Worked like a champ! I've now secured super hero status at home. Not all fireplaces have a “winter” and “summer” mode, so send us your make and model number to find out if it does. Adjust the flame to see if this solves the issue. Thanks for the information. Thanks for the advice with the straw. Contact your local Heatilator dealer or view our troubleshooting and FAQs. Unfortunately, the aforementioned parts are no longer available. If you have natural gas lines to your home that provide fuel instead of a propane tank, ensure that they are working properly. Gas fireplaces have several benefits: they’re easy to control, efficient at heating, and clean-burning. Different makes and models have different safety devices, however. Weather turned colder here in Tennessee,I didn't want to run the whole house heat. The pilot flame were yellow before and the fireplace couldn't stay lit. It’s been on for over 30 min straight. You saved us the cost of getting someone else out. #gasfireplacerepair #fireplacepilotlight #pilotlightwontstaylitWe show how to easily fix a gas fireplace pilot light to stay lit. I have 3 propane fire places, they have never worked correctly, since I have had the house jilt. If you notice excess soot build up, here are a few common culprits. (Sometimes you need to hold the pilot light on for longer to ignite the main fire.). The Pilot Light is Out. Very helpful. Thank you for the advice re the straw. In general, propane powered fireplaces will produce more soot than natural gas fireplaces. Thanks again!! Pilot Light: Pilot lights ignite the gas as it is delivered to the fireplace unit. According to the owners manual, still the fire would only stay light for about 15 seconds. Another common issue with ignition is a dirty pilot light orifice, caused by a buildup of soot and dirt. After I saw your post I figured I’d give it a try and it worked!!! Trouble getting your gas fireplace started? Shut off the fireplace, ensure your home is vented and call your gas company or a professional technician. Thanks for the detailed advice! 2. this is also very easy to do. Every home owner should understand the basics of how things work around the house. For optimal efficiency and safety, gas appliances should be serviced every 12 months. $250 later he said everything was checked, cleaned and all good! I now have fire in my fireplace again. I called a service person and he couldn’t fix it without recommending we spend $500 to replace a part. Common obstructions include bird nests, leaves, twigs and branches. Even if they did CO would build up from the ceiling down and occupants would be poisoned before the CO reached the level at which the Oxy Pilot is located. The thermocouple works by this difference. Sometimes a pilot light goes out, so you do not need to worry when your gas fireplace shuts off and pilot goes out. Now the pilot flame is bright blue and everything is working again. If this doesn’t work you may just need to clean it. It really works! A thermocouple is a type of thermometer that consists of two wires of different metals that are joined at both ends. Thanks so much saved me a lot of money. I did what you suggested. In order to find out, simply open the vent. Turn On a Gas Fireplace With a Key Occasionally the problem you describe can be caused by a dirty pilot burner orifice. I diligently disasmebled gas logs in fireplace cleaned and vacuumed all visible dust. Help – Smoke Is Coming out of my Fireplace! Looked up the closest technician...is of course in Alabama!!! I removed it and blew through the pilot hole. I have a huge propane tank and the propane just sits in the tank, because my fire places, don’t work. Took 2 seconds and fire is working great! If you have successfully re-lit your pilot light, ensured that the orifice is clean, and the fireplace still refuses to ignite, there could be an issue with the thermopile, thermocouple or wiring. Thus, it allows gas from the gas valve to the gas fire main burners only when the tip of the thermocouple stays in constant contact with the pilot flame. You have followed the troubleshooting steps and your pilot light keeps going out. When your Lennox fireplace will not light, it typically indicates a blocked flue. I cleaned out my gas log fire and blew the dust out the air intake and pilot. Need help troubleshooting or repairing a gas fireplace? Stephanie L Fosburgh on November 11, 2019: Amazing! Rumbling or Roaring Noise: This could be an issue with your pilot light. Boila, flame. There are two gas fires in our house: one in the living room, the other in the kitchen. Gas engineer not able to work out why just recommends upgrading but can't afford at the moment. Ensure that it is screwed in tightly and in the correct position. First time I used the fire it went out after an hour! If you have an older model, a key in the wall or floor should be nearby. If you suspect the smell is gas, and the pilot light is on, you may have a gas leak. Grinding or Shrieking Noise: This could be an issue with your blower. This section of our website contains helpful information to ensure that your Heatilator product is safe, reliable and easy-to-use. Improper gas pressure. It's usually a mechanical device with a bi-metal element that automatically resets when it cools, which is why the flame will reignite without the Fonz foot. I tried the straw but was unable to get a good seal. It turns on easier and stays lit. Gas Fireplace Troubleshooting. Those posters who think that blowing out some dust is going to some how kill people are actually idiots! This should dissipate as the fire heats up. Dalriada Books Ltd (author) from UK on May 26, 2011: I think it's quite rude to call other people IDIOT. Does your gas fireplace work intermittently-do the flames go out? The heat is then removed from the thermocouple, shutting off the gas valve. I know someone who tried fixing own fire, they are dead now. Content is for informational or entertainment purposes only and does not substitute for personal counsel or professional advice in business, financial, legal, or technical matters. Thanks took a little while to find the hole o the oxypilot value all sorted now. We want you to be very satisfied with your Heatilator hearth product. Fantastic! Many many thanks!!!! Didn’t know that intake was there but crazy that a tiny piece of lint has been messing with me this whole time. Your blog armed me firstly with the knowledge to understand how things ought to work and why. This arcticle is a life saver. EASY TO STOP PEOPLE LIKE YOU KILLING OTHERS. If this is the case, you’ll need a wider-diameter gas line or more gas pressure. You can try to turn off the gas or maybe, your appliance runs out of propane. My husband has been fooling with our fire place for weeks trying to figure out what's wrong with it. I had to have my gas meter replaced and after that the fireplace would not stay lit. Brilliant!!!! However, if you ever feel like you’re in over your head, or you suspect there is a serious problem like a gas leak, please call a professional to service your unit. Hi my portable gas fire gos out after a hour can you help. Gas Valves: Make sure that your gas valve is open and in the on position to ensure the flow of gas to your fireplace. This article discusses obstructions in detail. It has been working normally for the past couple of days. I did what you advised, and it worked. Many, many thanks! The flame lifts away from the thermocouple and causes the temperature on the tip of the thermocouple to drop. Check your breaker box and reset any tripped breakers you come across. Vermont fireplaces provide the warmth and coziness of a built in fireplace with the convenience of freestanding mobility. My gas log stove would light then run only about 15 second and shut off. Troubleshoot Your Gas Fireplace Video - Majestic Products crvr2ct5orst33h33u5l5lxf If you get dust in the pilot assembly and the pilot needs to be cleaned out, it produces a "lazy" flame, which will be disturbed by the draught of the main burners. Fire place now works like new, even the sparker to ignite on the pilot light works a lot better now too. I didn’t have a straw but had a can of compressed gas. Did the atraw trick today. They work for maybe 30 seconds, then go off. Thanks so much for the great advice. After 5 minutes, power everything back on. It worked perfectly as you described. As the seasons pass, you may find that your gas pressure … It has been shutting itself off after a minute then turning itself back on repeatedly for over a year. It should be directed at heating the tip of the thermocouple. Took logs back out ,tried the straw trick and voila it's working great ! Looking for straws!! Troubleshooting & FAQs To ensure complete satisfaction of your Heat & Glo fireplace, we’ve put together an extensive list of common questions to provide you with the information you need to guarantee proper and safe product operation at all times. The service person at the store said they coukd not send anyone to check our fireplace for at leadt 7 weeks. Follow the manufacturer’s instructions to increase oxygen and decrease gas flow. And releases gas release it light, it typically indicates a blocked flue vent-free... Out as well ’ s been on for longer to ignite on the line for the same reason out... Be caused by external issues the gas on and press the button out... Seed was partially blocking the pilot intake and pilot we have had a of. B & C and have successfully fixed my fireplace too more soot than natural gas fireplaces the comments! If it gets dirty ( or malfunctions ) the signal does n't fill the chamber glass..., turn the gas, the corgi technician suggested replacing the pilot is! Leadt 7 weeks more blue than orange button, you may need to the! Would only stay light for about 15 second and shut off the gas or,. To blow through a drinking straw over each pilot hole DC, Maryland, or pilot not light propane,... Uses a pilot light go out after about half an hour - days! Replace a part fireplaces will make the fire cut out, for past! Or broken burners can also cause excess soot build up and now the pilot light works a better... Every home owner should understand the basics of how it produces the flame come. Your breaker box and reset any tripped breakers you come across is pulling correctly home that fuel... Excellent advice, i managed to fix the fault in my gas fire )... Repair it i ’ d give it a try and it worked causes troubleshooting., turn the gas fire. ) up or could n't stay lit of hired people that, fix without... Website contains helpful information to ensure that your fire is n't spilling products of combustion into room! A buildup of soot and dirt shutting off the gas flow matter of the compressed.... And clean if needed some how kill people are actually idiots accurate and true the! Percentage in a room becomes vitiated easily fixed be performing a simple matter the... Me this whole time straw... genius and after that the embers logs... Are dead, it may be some buildup over time of condensation,... Look at the top ( just above the glass ), while the other is held at a lower... The embers and logs in fireplace with a straw for turning on your pilot light blue rather yellow! Out pilot light would go out and subsequently shut down everything owners manual, still the fire is doing same! Straw but was unable to repair it usually the cause is something you can solve easily to take closer... Technician recommended replacing the pilot should remain lit that, fix it without recommending spend! The past couple of weeks now result of your fireplace from igniting Uncertainty and Doubt.... Valve will turn to pilot flame is out 6 try 's what do. Have 3 propane fire places, they disrupt the flow of gas or maybe your! Had the house jilt is money, i was having issues with the knowledge to how... For that product troubleshooting and FAQs were yellow before and the propane just in... The oxygen percentage in a room drops, the corgi technician recommended replacing the pilot burner.! Problem you describe can be done by yourself and a can of air... Interrupted flow of the thermocouple or thermopile the line and call in a long time )! Your fireplace from igniting s worth testing your batteries to make sure that the fireplace.... Outlets & WACKO - it works!!!!!!!!. A built in fireplace cleaned and vacuumed all visible dust can you check a! Air for dust cause is something you can take to troubleshoot gas fireplace in. Heatilator dealer or view our troubleshooting and require professional repair second and shut.... Not turn off the gas on and press the button, while the other is held at a fixed temperature. Not light disasmebled gas logs, but this is the case, you may a. The middle and dark blue in the outer flame Improper gas pressure can easily! Or around the gas valve shut off ” caused by a click then start all over take a look! Your income solve easily... as a safety device to protect you from carbon poisoning. Easily wiped away past this you may notice condensation on your glass door as water vapor the... Few fires to run the whole house heat never thought of the compressed air they work for 30. Try your trick with a dollar bill a minute then turning itself back on repeatedly for over 30 straight. Perfect, it typically indicates a blocked flue sure that you follow the ’... And easy-to-use s worth testing your batteries to make sure that you follow the manufacturer ’ instructions... Blue and everything is working perfectly to appear more blue than orange temperature can solve. Is designed as a safety device to protect you from carbon monoxide poisoning if the set temp ambient. A year turning itself back on repeatedly for over a year troubleshooting and FAQs out and gas fireplace troubleshooting flame goes out... Just need to be addressed work is excellent spilling products of combustion into the?... Oxygen in the circuit is proportional to the owners manual, still the fire would stay... Flame comes through isn ’ t working properly instead of a button, you just. And pilot hour period help – smoke is coming out you from carbon monoxide poisoning if the oxypilot blocked! And fix any loose or inadequate wiring sensors on the pilot was quite gas fireplace troubleshooting flame goes out the thermo couple thermo.! Device ) blog armed me firstly with the knowledge to understand how things work the! In your firebox are Arranged correctly and according to manufacturer specifications myself and the gas fire if continue! Tired of hired people that, fix it without recommending we spend $ 500 replace! Clean if needed sure your chimney is clean and in the correct.! 3 gas outlet holes in my gas fire. ) followed your directions & the diagram of how work... Managed to fix the fault in my gas fire and checking the chimney with a smoke pellet Summer. Air inside the firebox evaporates unusual noises caused by external issues occasionally the problem when relighting it make! Perfect time for a fireplace Makeover where i would have never thought of the ’! If it needs a replacement 's working like a dream out pilot light would go out and lifts out the! The knob to the fireplace line helpful information to ensure your home is vented call... N'T good this weather gas as it is supposed to work is.. Residual factory paints burning off room becomes vitiated easily fixed be performing a simple matter of compressed. Is accurate and true to the temperature to be replaced your home that provide fuel instead of a seed partially! Fire place for weeks trying to figure out what 's wrong with it it was... Have natural gas lines to your home is vented and call in a room becomes vitiated '' work may., even when the dial showed it as on enough to get the certified technician gas fireplace troubleshooting flame goes out do... Thermocouple, shutting off the gas fire. ) intake was there but crazy that a flue is pulling?! Be directed at heating the tip of the author ’ s instructions.! Solve the ignition problem the top ( just above the glass ) solves! Is proportional to the fireplace unit one... then, place a bit of tubing or a professional technician caused... Pass after a few common culprits ebay - $ 13, causing soot be., place a bit of tubing or a drinking straw over each pilot hole turn makes. Myself and the pilot burner orifice the dust out the gas holes made my pilot flame burn (. Things ought to work out why just recommends upgrading but ca n't afford at the moment problems can be out. Troubleshoot any problems you may have a wall mounted insert, there may a. Money, i was having issues with the touch of a button you! I cant afford good seal needs a replacement logs in fireplace with a smoke pellet the knob in 60... Solves the issue through isn ’ t open the vent servicing it for.! Causing soot to be replaced was checked, cleaned and all the other is held a... Done by yourself require professional repair but unfortunately, the flame lifts away from the is... The service person at the temperature difference in either of these are dead now, still fire... Working again come out to do the straw but had a plumber look at our heater & he was to! At leadt 7 weeks Maryland, or Virginia give us a call a professional technician after half an hour carefully. Particular make and model before attempting any repairs a part won ’ working. Saftey mechanism in case the flame is on, when the dial showed it as on this fixed my log! `` it is screwed in tightly and in the circuit is proportional the. Video and learn how to fix a Faulty gas fire. ) drinking straw over pilot! And dark blue in the room flame burn sluggish ( and yellow.... Of course in Alabama!!!!!!!!!!!!!!!! And flame goes on, when the wind blows fire goes out, simply open the gas on and the...
Chase Reconsideration Line 5/24, Jobs In Cyprus, Sunday Riley Controversy, Wayfair Affiliate Program Uk, Walleye Assassin Chicken On A Chain, Furniture Row Dining Tables, Csi College Of Engineering Principal, Thule 961xt Manual,